OMRON E5EN-C301T-FLK-N INSTRUCTION Manual PDF
Product model: E5EN-C301T-FLK-N
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling E5EN-C301T-FLK-N PDF.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal) E5EN-C301T-FLK-N
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure E5EN-C301T-FLK-N PDF.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP E5EN-C301T-FLK-N PDF.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver E5EN-C301T-FLK-N Manual. 4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output OMRON INSTRUCTION Manual.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. The main body: terminal type, temperature input type OMRON INSTRUCTION Manual.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply OMRON INSTRUCTION Manual.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5EN-C301T-FLK-N INSTRUCTION Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5EN-C301T-FLK-N Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.