LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON E5CC-TRX3ASM-066 INSTRUCTION Manual PDF
Product model: E5CC-TRX3ASM-066
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
E3Z-T67-G0 detection methods: the firing pattern.
Connection: socket type (M8).
Detection range: 30m.
Output mode: NPN output.
Achieve small, long distance, save electricity and
Standard type of photoelectric sensor for energy saving
Size: 96 x 96mm E5CC-TRX3ASM-066 PDF.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling E5CC-TRX3ASM-066
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input E5CC-TRX3ASM-066 PDF.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0 E5CC-TRX3ASM-066 PDF. 01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP E5CC-TRX3ASM-066 Manual.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV OMRON INSTRUCTION Manual.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication OMRON INSTRUCTION Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Analog (current/voltage) OMRON INSTRUCTION Manual.
Alarm output: 2.
option units Mounting: Yes.
Control output: Voltage output(for driving SSR).
Previous mode: None.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models availlable with a loop break alarm (LBA) and,
heater short alarm (HS alarm) E5CC-TRX3ASM-066 INSTRUCTION Manual.
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protoocol called Modbus is installed in the models,
with communications E5CC-TRX3ASM-066 Manual.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.
Related products