Sensing distance: (See note 2.)0 to 3.5 mm(pressed position) (See note 1.).
Sensing method: Pushbutton.
Operation mode: OFF with no load.
Cable length: 1 m (robot cable) E5CC-CX2DSM-004 PDF.
Model: PNP output .
Using a pushbutton enables,
accurately detecting difficult-to-detec objects.
Conforms to standards for semiconductor FOUP cassettes to ena,
accurately detecting FOUP cassettes without being affected by the,
material, color, or reflectance of the bottoms of the cassettes
E5CC-CX2DSM-004
Thin design enables mounting in a wider range of applications, e.g.,
on transfer arms.
Increased visibility with 4-direction indicator E5CC-CX2DSM-004 PDF.
Optical detection of actuator operation provides a long life,
(mechanical life: 5 million operations min.).
Models available with PNP or NPN output.
Models are available with very flexible robot cable. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: posittion ratio with relay output E5CC-CX2DSM-004 PDF E5CC-CX2DSM-004 Manual.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 4 OMRON INSTRUCTION Manual.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure OMRON INSTRUCTION Manual.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV OMRON INSTRUCTION Manual.
Through the support software (Ver.4.3 CX-Thermo) makees the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5CC-CX2DSM-004 INSTRUCTION Manual.
Through the infrared port can be carried out from the frront of the communication E5CC-CX2DSM-004 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.