Product model: E3S-R2E42
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 4.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2 E3S-R2E42 PDF.
Control outputs 3 and 4: Voltage output: 2 points (for SSR drive) *2.
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, None .
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485 E3S-R2E42
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp E3S-R2E42 PDF.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design E3S-R2E42 PDF.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise OMRON INSTRUCTION sheet.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceNNet,
Communications Unit OMRON INSTRUCTION sheet E3S-R2E42 Manual. Size: 96 x 96mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input OMRON INSTRUCTION sheet.
Heating wire break, SSR fault detection function: -.
Communication: -.
Event input: 4 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output andd remote SP input, suitable for a wide range of applications E3S-R2E42 INSTRUCTION sheet.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperrature controller is connected to each other by using the component communication E3S-R2E42 Manual.
A new type of proportional control allows you to control the valve.
Related products
OMRON
Transparent Object Detection Sensor
E3S-R11
OMRON Transparent Object Detection Sensor E3S-R11
Sensing method: Retro reflective. Appea
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AT11
OMRON Built-in Amplifier Photoelectric Sensor E3S-AT11
Sensing method: Through-eam Sensors. A
OMRON
Identification sensor
E3S-VS1C4
OMRON Identification sensor E3S-VS1C4
Choose red, green light source of the 2
OMRON
PCB Sensors
E3S-LS3NWT
OMRON PCB Sensors E3S-LS3NWT
Sensing method: Convergent reflective.