LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON E2E-S04SR8-WC-C1 INSTRUCTION sheet PDF
Product model: E2E-S04SR8-WC-C1
Name: proximity sensor
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Size: 96 x 96mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V E2E-S04SR8-WC-C1 PDF.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: -.
Communication: -.
Event input: 6 points.
Remote SP input: there.
Transfer output: have E2E-S04SR8-WC-C1
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm E2E-S04SR8-WC-C1 PDF.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately) E2E-S04SR8-WC-C1 PDF.
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC) OMRON INSTRUCTION sheet.
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Size: 48 x 96mm E2E-S04SR8-WC-C1 Manual.
Type: power AC/DC24V with.
Shell color: black OMRON INSTRUCTION sheet.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal) OMRON INSTRUCTION sheet.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makess the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E2E-S04SR8-WC-C1 INSTRUCTION sheet.
Through the infrared port can be carried out from the frront of the communication E2E-S04SR8-WC-C1 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.