Product model: E2E-C04N03-CJ-C2
Name: proximity sensor
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling E2E-C04N03-CJ-C2 PDF.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input E2E-C04N03-CJ-C2
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved E2E-C04N03-CJ-C2 PDF.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors E2E-C04N03-CJ-C2 PDF.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output OMRON INSTRRUCTION sheet E2E-C04N03-CJ-C2 Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling OMRON INSTRUCTION sheet.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-Q1TC;
Resistance thermometer input, E5GN-Q1P.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance OMRON INSTRUCTION sheet. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temmperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E2E-C04N03-CJ-C2 INSTRUCTION sheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E2E-C04N03-CJ-C2 Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.