OMRON D4N-8122 INSTRUCTION sheet PDF
Product model: D4N-8122
Name: safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Actuator: Plunger.
Conduit openings: M20.
2NC (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification D4N-8122 PDF.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever D4N-8122
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion D4N-8122 PDF.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13).
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Operation indicator: With operating indication; Standard load D4N-8122 PDF.
Ratings: 5 A at 125 VAC.
Actuator: Adjustable roller lever.
Cable length : 3m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA,, and CCC (Chinese standard) D4N-8122 Manual.
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection OMRON INSTRUCTION sheet.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models OMRON INSTRUCTION sheet.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models OMRON INSTRUCTION sheet. ) Release key type: Special release key.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns D4N-8122 INSTRUCTION sheet.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas. D4N-8122 Manual.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.
Related products
OMRON
Safety Limit Switch
D4N-2F31
OMRON Safety Limit Switch D4N-2F31
Actuator: Plunger. Conduit size: 1-cond
OMRON
Safety Limit Switch
D4N-9222
OMRON Safety Limit Switch D4N-9222
Actuator: Roller lever resin lever, res
OMRON
Safety Limit Switch
D4N-2E22
OMRON Safety Limit Switch D4N-2E22
Actuator: Roller lever metal lever, res
OMRON
Pull-reset Safety Limit Switch
D4N-2C31R
OMRON Pull-reset Safety Limit Switch D4N-2C31R
Actuator: Plunger. Conduit size: 1-cond