LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON D4N-4222 INSTRUCTION sheet PDF
Product model: D4N-4222
Name: safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
The drive rod: rod type Shibai leaf.
Contact specifications: 1a.
Rating: general load with 1A.
For the automobile, industrial vehicles, mechanical testing of the anti immersion type (in line with IP67)
Use M4 screw to achieve a little installation D4N-4222 PDF.
Using a strong fixed leaf swing rod which can adapt to the harsh environment.
Full consideration of environmental protection, the installation of the wire also lead to lead free D4N-4222 Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release D4N-4222 PDF.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
D4N-4222 PDF.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal. D4N-4222 Manual.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point OMRON INSTRUCTION sheet.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames OMRON INSTRUCTION sheet.
The plastic material makes the Slide Key suitable,
for lightweight doors. Actuator: Adjustable roller lever.
Conduit openings: M20.
2NC (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification OMRON INSTRUCTION sheet.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the leever D4N-4222 INSTRUCTION sheet.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4N-4222 Manual.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Related products
OMRON
Safety Limit Switch
D4N-4A32
OMRON Safety Limit Switch D4N-4A32
Actuator: Roller plunger. Conduit size:
OMRON
Safety Limit Switch
D4N-4262
OMRON Safety Limit Switch D4N-4262
Actuator: One-way roller arm lever hori
OMRON
Pull-reset Safety Limit Switch
D4N-2C31R
OMRON Pull-reset Safety Limit Switch D4N-2C31R
Actuator: Plunger. Conduit size: 1-cond
OMRON
Safety Limit Switch
D4N-2C32
OMRON Safety Limit Switch D4N-2C32
Actuator: Roller plunger. Conduit size: