LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON D4N-3A31R INSTRUCTION sheet PDF
Product model: D4N-3A31R
Name: pull-reset safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Actuator: Plunger.
Conduit openings: M20.
1NC/1NO (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification D4N-3A31R PDF.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever D4N-3A31R
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion D4NN-3A31R PDF D4N-3A31R Manual.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13).
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Release Key Type: Standard (metal).
Wiring method: Terminal block D4N-3A31R PDF.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note OMRON INSTRUCTION sheet. ): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices OMRON INSTRUCTION sheet.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without deetaching the head D4N-3A31R INSTRUCTION sheet.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming OMRON INSTRUCTION sheet.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4N-3A31R Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Safety Limit Switch
D4N-8C2H
OMRON Safety Limit Switch D4N-8C2H
Actuator: Adjustale roller lever, form
OMRON
Safety Limit Switch
D4N-4F31
OMRON Safety Limit Switch D4N-4F31
Actuator: Plunger. Conduit size: 1-cond
OMRON
Safety Limit Switch
D4N-1C2H
OMRON Safety Limit Switch D4N-1C2H
Actuator: Adjustale roller lever, form
OMRON
Safety Limit Switch
D4N-9A62
OMRON Safety Limit Switch D4N-9A62
Actuator: One-way roller arm lever hori