OMRON D4JL-2NFA-C7-01 INSTRUCTION sheet PDF
Product model: D4JL-2NFA-C7-01
Name: guard lock safety-door switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed pin plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also D4JL-2NFA-C7-01 PDF.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection D4JL-2NFA-C7-01
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models D4JL-2NFA-C7-01 PDF.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation D4JL-2NFA-C7-01 Manual.
(Set by default to light for non-operation D4JL-2NFA-C7-01 PDF. )
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Determine the vibration of equipment and machinery.
With the aid of vibration level can be easily recognized, set the ON/OFF output.
Confirm vibration waveform by AC monitor output.
Sensor part of the use of IP67 protection structure, can also be used in harsh environments OMRON INSTRUCTION sheet.
Can switch acceleration, speed (linear output type).
Using 5 processing modes to determine the abnormal state of high accuracy (manual setting).
Ontology: part of the controller.
Type: manual setting. Type: 1-conduit OMRON INSTRUCTION sheet.
Mounting direction: Front-side mounting.
Conduit size: G1/2.
2NC (Slow-action).
The Special Operation Key Activates a Direct.
Opening Mechanism to Open the Contacts.
and Shut Off Control Circuits when Protective.
Doors Are Opened on Machine Tools or Other.
Equipment.
Conforms to EN (TÜV) standards corresponding to the CE marking OMRON INSTRUCTION sheet.
Certified by UL and CSA standards.

The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened D4JL-2NFA-C7-01 INSTRUCTION sheet. The EN-certified.
direct opening mechanism is indicated by on the Switch.
Malfunctions and false operationn prevented by special Operation Key D4JL-2NFA-C7-01 Manual.
Wide temperature range specifications: −40 to 80°C.
Degree of protection of the switch box: IP67 (EN60947-5-1).