Actuator: Pin plunger.
Type: M8.
Operation Indicator: Provided.
Repeat accuracy: 1 µm max.
Operating force OF max: 0.49 N.
Cable lead outlet: Lead outlet, Pre-wired; Length, 1 m D4JL-1PFA-C6 PDF.
Degree of protection: IP67.
High-precision Switch for Detecting Micron-unit,
Displacement.
Ideal for detecting and measuring wear of cutting,
tools or for original point of work.
Ceramic plungers on M5, M8, and slim models for,
superior abrasion resistance and resistance to,
temperature changes
D4JL-1PFA-C6
Direct input possible to microprocessors and,
programmable controllers.
A version with screw-type cable connector available,
for easy installlation and maintenance D4JL-1PFA-C6 PDF D4JL-1PFA-C6 Manual. Short/disconnection detection: Supported.
Specifications: Inputs, PNP (- common), 16 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC D4JL-1PFA-C6 PDF.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. Actuator: Roller lever (resin roller) OMRON INSTRUCTION sheet.
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts OMRON INSTRUCTION sheet.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Equipped with a mechaniism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion OMRON INSTRUCTION sheet D4JL-1PFA-C6 INSTRUCTION sheet.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4JL-1PFA-C6 Manual.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.