LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI QS90SR2SN-Q Safety Application Guide PDF
Product model: QS90SR2SN-Q
Name: PLC
Brand: MITSUBISHI
Sort: Safety Application Guide
File language: English
The telephone line of the interface module is connected with the peripheral equipment.Input / output points: 4096 points.
Size side mode: small end mode QS90SR2SN-Q PDF.
SD memory card: available.
Q24DHCCPU-LS without OS.
C language controller is a long term stable supply, high reliability, high performance, flexible MELSEC on the implementation of the C language program revolutionary open platform QS90SR2SN-Q
Including pre installed VxWorks,
This C language controller can be used with various modules of the MELSEC-Q series,
Partner products and open source,
Client program assets, such as portfolio use to build a variety of systems QS90SR2SN-Q PDF.
As can be used in all scenarios, can replace the computer, a new computer platform,
C MELSEC language controller stronger, simpler, higher performance, more flexible, in the future will also continue to continue to develop QS90SR2SN-Q Manual.
Output points: 4 points (select the source type + drain type), 2 points (select the source type + source) QS90SR2SN-Q PDF.
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system MITSUBISHI Safety Application Guide.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures MITSUBISHI Safety Application Guide.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down MITSUBISHI Safety Application Guide QS90SR2SN-Q Safety Application Guide. Battery replacement.
Initial voltagge 3 QS90SR2SN-Q Manual. 0V.
Replacement of large capacity battery module without cable.
Current capacity: 18000mAh.
Service life: 5 years.
Outline dimension: 98*55.2*87mm.
Related products
MITSUBISHI
Safety relay module
QS90SR2SP-CC
MITSUBISHI Safety relay module QS90SR2SP-CC
Meet safety standards: EN954-1 class 4,
MITSUBISHI
Safety relay module
QS90SR2SP-EX
MITSUBISHI Safety relay module QS90SR2SP-EX
Application: extension. Suitale for saf
MITSUBISHI
Safety relay module
QS90SR2SP-Q
MITSUBISHI Safety relay module QS90SR2SP-Q
Application: Q series. Suitale for safe
MITSUBISHI
Safety relay module
QS90SR2SN-CC
MITSUBISHI Safety relay module QS90SR2SN-CC
Meet safety standards: EN954-1 class 4,