LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI QS001CPU Programming Guide Book (Structured Text) PDF
Product model: QS001CPU
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text Programming Guide Book
File language: English
MODBUS RTU/MODBUS ASCII Master slave station.
RS-232.
RS-422/485.
MODBUS interface module capable of connecting MODBUS compatible device such as temperature regulator, measuring device and so on QS001CPU PDF.
Support MODBUS communication function, and can be compatible with the third party MODBUS to communicate from various station equipment.
Support MODBUS communication functions from the station, can communicate with the third party programmable controller MODBUS master device QS001CPU
Through the linkage function, the master can be connected to the CH1 side (RS-232),
And through the QJ71MB91 and connected to the CH2 side (RS-422/485) of a number of stations for communication QS001CPU PDF.
The RS-232 interface (1 credit on the 1 pass) MODBUS master device with multiple MODBUS communication from the station equipment. (only QJ71MB91)
Master / slave station functions can be used simultaneously. (only QJ71MT91)Input: 8 channels QS001CPU PDF.
30kpps/10kpps/1kpps/100pps/50pps/10pps/1pps/0.1pps.
Counter input signal: DC5/12-24V.
The module is suitable for the measurement of the number of input pulses, such as speed, speed, instantaneous flow rate and so on,
As well as the quantity, the length, the cumulative flow and so on the measurement MITSUBISHI Programming Guide Book.
Input pulse values are updated every 10ms.
The number of pulses (sampling pulse number), which can be accumulated and processed by the moving average, is updated according to the counting period. Input points: 32 points.
Input voltage and current: 4mA DC24V.
Response time: 1/5/10/20/70ms.
32 point /1 a public side MITSUBISHI Programming Guide Book.
Common anode.
40 pin connector.
Easy connection programming tool via ethernet QS001CPU Manual .
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used MITSUBISHI Programming Guide Book.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file passwword QS001CPU Programming Guide Book.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorizeed access to unauthorized users QS001CPU Manual .
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
Related products
MITSUBISHI
Basic type CPU
Q01CPU
MITSUBISHI Basic type CPU Q01CPU
Program capacity: 8K step. Input / outpu
MITSUBISHI
Secure CPU module
QS001CPU
MITSUBISHI Secure CPU module QS001CPU
Control mode: loop program execution. In