MITSUBISHI QJ71C24-R2 Reference Manual PDF
Product model: QJ71C24-R2
Name: Communication Protocol
Brand: MITSUBISHI
Sort: Reference Manual
File language: English
Three-phase 4 wire type.
Measuring circuit number: 1 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc QJ71C24-R2 PDF. .
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information QJ71C24-R2
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm QJ71C24-R2 PDF.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity inn the unit of the beat can be obtained during the operation of the equipment QJ71C24-R2 Manual.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products QJ71C24-R2 PDF.
For example, a module can be used to measure other loads from the control panel trunk.
In addition, Works2 GX (version 1 MITSUBISHI Reference Manual. 90U and higher) can be used to easily set parameters.GI-50/125 optical cable.
Double ring.
PLC to PLC network (control station / common station) / remote I/O network / (remote master station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station MITSUBISHI Reference Manual.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of tthe total cable length, strong anti-interference MITSUBISHI Reference Manual QJ71C24-R2 Reference Manual.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system QJ71C24-R2 Manual. ..... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.