LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI Q172DCPU-S1 Programming Manual (Application Functions) PDF
Product model: Q172DCPU-S1
Name: PLC
Brand: MITSUBISHI
Sort: Application Functions Programming Manual
File language: English
5 slots; dual supply mode power supply redundancy system;
Used to install Q series modules.
Redundant CPU expansion for the first time dedicated.
Reduce system downtime recovery time Q172DCPU-S1 PDF.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance Q172DCPU-S1
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown Q172DCPU-S1 PDF.
Wider application range, more advanced.
Leading in the era of the Q series CPU products.
Q series CPU products a wide range of applications,
Provide programmable controller, process, redundancy, C language, movement, manipulator, CNC all kinds of CPU,
In order to meet the needs of various control Q172DCPU-S1 PDF.
Through the multi CPU configuration, can be based on the use of the scale, purpose,
Construction of the best system to meet the requirements of all kinds of control.
In addition, the high reliability system can be constructed by the redundant system,
Even if a fault occurs, the system can continue to run MITSUBISHI Programming Manual. Input: 4 channels.
Platinum resistance (Pt10; JPt100).
Conversion speed: 40ms/1.
Channel 18 point terminal.
Platinum thermal resistance (Pt100, JPt100).
Nickel thermal resistance (Ni100).
Shedding detecction function Q172DCPU-S1 Manual .
Conversion speed: 320ms/8 channel MITSUBISHI Programming Manual.
Inter channel isolation.
40 pin connector.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use MITSUBISHI Programming Manual.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the lloss of the program and the parameters due to forgetting to replace the battery Q172DCPU-S1 Programming Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and otther planned downtime,
The data is lost due to battery depletion Q172DCPU-S1 Manual .
The next time the power is turned on, the backup data will be automatically restored.
Related products
MITSUBISHI
Motion controller
Q170MSCPU-S1
MITSUBISHI Motion controller Q170MSCPU-S1
Control axis: up to 16 axes. Interpolati
MITSUBISHI
CPU unit
A2NCPU-S1
MITSUBISHI CPU unit A2NCPU-S1
Input and output points: 1024 points. In
MITSUBISHI
Motion CPU module
Q172DCPU
MITSUBISHI Motion CPU module Q172DCPU
Control axis: maximum 8 axes. Peripheral