MITSUBISHI Q170MSCPU Programming Manual (SFC) PDF
Product model: Q170MSCPU
Name: CPU
Brand: MITSUBISHI
Sort: SFC Programming Manual
File language: English
Input / output points: 4096 points.
Number of input and output elements: 8192.
Program capacity: 100 K step.
Processing speed: 0.0095 s.
Program memory capacity: 400 KB Q170MSCPU PDF.
Support USB and RS232.
Support installed memory card.
Providing high speed communication between multiple CPU.
High speed and high precision data processing.
The processing speed of the real number (floating point) arithmetic has been greatly improved,
Addition instruction reached 0 Q170MSCPU014 mu s,
Therefore, it can support the request of high-speed, high-precision processing data processing.
In addition, the new addition of double precision floating point arithmetic instructions,
Simplify the programming, reduces the computational error when executing complex formula Q170MSCPU PDF.
Shorten the fixed scan interrupt time, high precision device.
The minimum interval of the fixed period interrupt program is reduced to 100 s.
The high speed signal can be accurately obtained, which makes the contribution to the higher precision of the device Q170MSCPU PDF. 10BASE-T/100BASE-TX.
Ethernet interface module capable of selecting the most suitable system and object device.
Support 100BASE-TX, can speed up the transmission speed. (QJ71E71-100)
Data communication can be performed between programmable controller CPU using special instructions MITSUBISHI Programming Manual .
Can use the HTTP protocol, through the Web browser on the PC access to the soft element of the programmable controller.
PC (Web) on the use of the communication program library and sample screen can be obtained by download services MITSUBISHI Programming Manual .
Can connect a number of programming tools to improve the efficiency of debugging.
Make use of e-mail function, through the mail server to send e-mail (ASCII format) and attachments (binary, ASCII and CSV format).
The KeepAlive function can be used to perform the existence of the object equipment inspection, and keep the connection in the open state MITSUBISHI Programming Manual .
This can be used to ensure connectivity and to quickly find errors. Output points: 16 points.
Output voltage and current: DC12~24V; 0.5A/ point; 4A/ common.
OFF leakage current: 0.1mA.
Response time: 1ms.
16 points and 1 common ends.
Source type.
18 point spring clip connection terminal.
With the surge absorber.
With fuse.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming.
The SRAM 8MB extension card is installed in the hiigh speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming Q170MSCPU Manual.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the extension to the file register to all regions of the file register.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured data (array),
The speed has been improved.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.
With the help of sample tracking function, the starting time is shortened
By using the sampling and tracking function, it is convenient to analyze the data when the fault occurs,
Testing procedures for the time, etc., can shorten the time of failure analysis and start-up time.
In addition, the multi CPU system also helps to determine the daata transceiver time between the CPU module Q170MSCPU Programming Manual .
Can be used to analyze the data collected by programming tools,
In the form of charts and trend charts, the data changes of the bit soft element and the word soft element can be easily diisplayed Q170MSCPU Manual.
And the sampling tracking results can be stored in LogViewer GX form CSV,
By recording data display and analysis tool LogViewer GX to display.
Related products
MITSUBISHI
CPU unit
A2ASCPU
MITSUBISHI CPU unit A2ASCPU
I/O points: 512. Processing speed: sec/
MITSUBISHI
Motion controller
Q170MSCPU-S1
MITSUBISHI Motion controller Q170MSCPU-S1
Control axis: up to 16 axes. Interpolati
MITSUBISHI
Motion controller
Q173DSCPU
MITSUBISHI Motion controller Q173DSCPU
Control axis: up to 32 axes. Servo ampli
MITSUBISHI
Motion controller
Q172DSCPU
MITSUBISHI Motion controller Q172DSCPU
Control axis: up to 16 axes. Servo ampli