Input: 4 channels.
Input: DC-10~10V, DC0~20mA.
Output (resolution): 0~4000, -4000~4000, 0~12000, 0~16000, -16000~16000.
Conversion speed: 500 s/1 channel Q13DUVCPU PDF.
18 point terminal.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller
Q13DUVCPU
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output Q13DUVCPU PDF.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required Q13DUVCPU PDF.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation aanalog module Q13DUVCPU Manual. Compact flash memory card.
Capacity: 4GB bytes. SRAM memory card, capacity: 1M bytes.
Size: 45*42.8*3.3mm
Weight: 15g.
Support SD memory card.
High speed universal QCPU support SD memory card,
In order to be able to have a memory card port between SD and PC to easily realize data exchange MITSUBISHI Programming Manual .
In addition, the SD memory card and the extended SRAM card can be used simultaneously.
Therefore, the extension of the file register using the extended SRAM card,
SD memory card can be used at the same time to carry out the data file record, a large number of annotation data storage, through the memory card to guide operation MITSUBISHI Programming Manual .
Better user experience data recording function.
Easy to record, no need to program.
Simply through the special configuration tool wizard to easily complete the settings,
The collected data can be saved in CSV format to SD storage card MITSUBISHI Programming Manual .
Can be effectively used to save the CSV file to facilitate the creation of a variety of reference materials,
Including daily reports, generate reports annd general reports Q13DUVCPU Programming Manual .
These data can be applied to the data analysis, tracing, etc..
To record the change of control data without missing.
Data can be collected in a time interval or in a millisecond time interval,
To record the changge of the specified control data without any omission Q13DUVCPU Manual.
Therefore, in the event of failure, can quickly determine the cause, the precise action analysis.