"4 axes, SSCNET III type.
2 axis /4 axis /3 axis linear interpolation.
2 axis interpolation.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis Q12HCPU PDF.
40 pin connector.
Through the SSCNET III cable connection to save wiring, the distance between the station up to 50m.
Absolute position system for determining the origin position is supported by the return data set operation Q12HCPU
In addition, the limit switch of the upper limit, the lower limit switch and the near point block signal input can be directly connected to the servo amplifier,
Thus greatly reducing the wiring requirements.
Easy to achieve high speed, high precision positioning control Q12HCPU PDF.
Support for multiple types of positioning control,
Including 2 ~ 4 axis 2 axis linear interpolation, circular interpolation, speed control and speed / position control, path switching control, constant speed control etcc Q12HCPU Manual. .
In addition, can use the "Configurator-QP GX" and other software,
Easy to set, monitor and debug Q12HCPU PDF. "Input points: 8 points (dual input), 16 points (single input).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Output points: 4 points (select the source type + drain type), 2 points (when selecting the source type + source) MITSUBISHI Programming Manual.
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system MITSUBISHI Programming Manual.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control proceedures MITSUBISHI Programming Manual Q12HCPU Programming Manual.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q12HCPU Manual.
Related products
MITSUBISHI
CPU unit
Q2ASHCPU
MITSUBISHI CPU unit Q2ASHCPU
Input and output points: 512 points. Inp
MITSUBISHI
CPU unit
A0J2CPU
MITSUBISHI CPU unit A0J2CPU
Input and output points: 480 points. Pro
MITSUBISHI
Process CPU
Q25PHCPU
MITSUBISHI Process CPU Q25PHCPU
Program capacity: 252 K step. Input / ou
MITSUBISHI
General purpose CPU
Q26UDHCPU
MITSUBISHI General purpose CPU Q26UDHCPU
Input / output points: 4096 points. Num