LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI Q12DCCPU-V Reference Manual (Communication Protocal) PDF
Product model: Q12DCCPU-V
Name: PLC
Brand: MITSUBISHI
Sort: Communication Protocal Reference Manual
File language: English
PCI bus.
Support Japanese, English OS.
SI/QSI/H-PCF/ broadband H-PCF cable.
Dual loop controller network (control station / common station).
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module Q12DCCPU-V PDF.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps Q12DCCPU-V
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time Q12DCCPU-V PDF.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation Q12DCCPU-V PDF.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings MITSUBISHI Reference Manual.
Only need to set up the transmission speed in the master module, you can uuse the remote I/O Q12DCCPU-V Manual. Set high performance CNC and high speed programmable controller as a whole.
Integrating the high performance CNC with the high speed programmable controller helps to shorten the overall cycle time MITSUBISHI Reference Manual.
Support a rich variety of FA modules, can be flexible to meet the needs of different applications.The input and output module installation number: 4.
Could extend the connection: not to extend the connection.
Application module: QS series module.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system MITSUBISHI Reference Manual.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outsidee the standard control procedures Q12DCCPU-V Reference Manual.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q12DCCPU-V Manual. "
Related products
MITSUBISHI
C language CPU
Q24DHCCPU-V
MITSUBISHI C language CPU Q24DHCCPU-V
Input / output points: 4096 points. Size
MITSUBISHI
C语言CPU电缆
Q12DCCPU-CBL
MITSUBISHI C语言CPU电缆 Q12DCCPU-CBL
RS232 connector conversion cale round
MITSUBISHI
C language CPU
Q06CCPU-V
MITSUBISHI C language CPU Q06CCPU-V
Input / output points: 4096 points. You
MITSUBISHI
C language controller module
R12CCPU-V
MITSUBISHI C language controller module R12CCPU-V
Memory capacity: 256MB. As one of the sp