MITSUBISHI Q06CCPU-V User's Manual (Hardware Design, Maintenance and Inspection) PDF
Product model: Q06CCPU-V
Name: CPU
Brand: MITSUBISHI
Sort: Hardware Design, Maintenance and Inspection User's Manual
File language: English
Input / output points: 4096 points.
Number of input and output elements: 8192.
Program capacity: 30 K step.
Processing speed: 0.02 s.
Program memory capacity: 120 KB Q06CCPU-V PDF.
Support USB and network.
Support installed memory card.
Providing high speed communication between multiple CPU.
Shorten the fixed scan interrupt time, high precision device.
The minimum interval of the fixed period interrupt program is reduced to 100 s Q06CCPU-V
The high speed signal can be accurately obtained, which makes the contribution to the higher precision of the device.
High speed and high precision machine control by multi CPU Q06CCPU-V PDF.
By parallel processing of the linear and multi CPU high-speed communication (cycle 0.88ms) of the parallel control program, the high speed control.
Multi CPU high speed communication cycle and motion control synchronization, so it can achieve the maximization of computing efficiency.
In addition, the latest movement control CPU in perrformance is 2 times the previous model,
To ensure high speed and high accuracy of the machine control Q06CCPU-V PDF Q06CCPU-V Manual. Input: 2 channels.
Input: thermocouple / micro voltage / voltage / current.
Conversion speed (input):25ms/2 channel.
Sampling period: 25ms/2 channel.
Output: DC4~20mA MITSUBISHI User's Manual.
Conversion speed (output):25ms/2 channel.
18 point terminal station.
With 5 kinds of PID control mode.
Loop control module suitable for fast response object control, such as temperature control, flow control, etc..
The loop control module has a PID control format and a sampling period of 25ms that is proportional to the speed,
Support high precision, high resolution Thermocouple Input, micro voltage input, voltage input, current input and current output MITSUBISHI User's Manual.
The most suitable for high speed lift and temperature control and pressure control, flow control and other requirements of the application of high speed response MITSUBISHI User's Manual.
Can be connected with JIS, IEC, NBS, ASTM standard thermocouple.
Through the small voltage, voltage, current input sensor, can be meassured in a variety of input range of analog Q06CCPU-V User's Manual.
Provides the program control function, can according to the specific requirements of the time automatically change the target value (SV) and PID constant [proportional band (P), integratiion time (I), differential time (D)],
And cascade control function, allowing channel 1 as the main station, channel 2 for the control from the station Q06CCPU-V Manual.
Related products
MITSUBISHI
C language CPU
Q06CCPU-V
MITSUBISHI C language CPU Q06CCPU-V
Input / output points: 4096 points. You
MITSUBISHI
C language CPU
Q06CCPU-V-H01
MITSUBISHI C language CPU Q06CCPU-V-H01
Input / output points: 4096 points. You
MITSUBISHI
C language controller module
R12CCPU-V
MITSUBISHI C language controller module R12CCPU-V
Memory capacity: 256MB. As one of the sp
MITSUBISHI
C language CPU
Q12DCCPU-V
MITSUBISHI C language CPU Q12DCCPU-V
Input / output points: 4096 points. You