MITSUBISHI Q06CCPU-V-B Programming Manual (Special Instructions) PDF
Product model: Q06CCPU-V-B
Name: PLC
Brand: MITSUBISHI
Sort: Special Instructions Programming Manual
File language: English
Three-phase 3 wire type.
Measuring circuit number: 1 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc Q06CCPU-V-B PDF. .
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information Q06CCPU-V-B
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm Q06CCPU-V-B PDF.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products Q06CCPU-V-B PDF.
For example, a module can be used to measure other loads from the control panel trunk.
In addition, Works2 GX (version 1 MITSUBISHI Programming Manual. 90U and higher) can be used to easily set parameters.Output points: 64 points.
Output voltage and current: 24V ~ 0.2A/1 DC5 point.
2A/1 common end.
OFF leakage current: 0.1mA.
Response time: 1ms.
32 points and 1 common ends.
Leaky type.
40 pin connector.
With heat protection.
With short circuit protection MITSUBISHI Programming Manual.
With the surge absorber.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time.
The operation period can be shortened by the super high basic operation speed 1 MITSUBISHI Programming Manual. 9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming.
The SRAM 8MB extension card is installed in the hiigh speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming Q06CCPU-V-B Manual.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the extension to the file register to all regions of the file register.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured data (array),
The speed has been improved.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.
With the help of sample tracking function, the starting time is shortened
By using the sampling and tracking function, it is convenient to analyze the data when the fault occurs,
Testing procedures for the time, etc., can shorten the time of failure analysis and start-up time.
In addition, the multi CPU system also helps to determine the dataa transceiver time between the CPU module Q06CCPU-V-B Programming Manual.
Can be used to analyze the data collected by programming tools,
In the form of charts and trend charts, the data changes of the bit soft element and the word soft element can be easily diisplayed Q06CCPU-V-B Manual.
And the sampling tracking results can be stored in LogViewer GX form CSV,
By recording data display and analysis tool LogViewer GX to display.
Related products
MITSUBISHI
C language CPU
Q06CCPU-V-H01
MITSUBISHI C language CPU Q06CCPU-V-H01
Input / output points: 4096 points. You
MITSUBISHI
C language CPU
Q06CCPU-V-B
MITSUBISHI C language CPU Q06CCPU-V-B
Input / output points: 4096 points. You
MITSUBISHI
C language CPU
Q06CCPU-V
MITSUBISHI C language CPU Q06CCPU-V
Input / output points: 4096 points. You