LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI Q03UDCPU Programming Guide (Structured Text) PDF
Product model: Q03UDCPU
Name: Programmable Controller
Brand: MITSUBISHI
Sort: Structured Text Programming Guide
File language: English
Q6TA32 special tool.Input and output points: 4096 points.
Input / output data points: 8192 points.
Program capacity: 124k.
Basic command processing speed (LD command) S:0 Q03UDCPU PDF. 075.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of Q03UDCPU
The photoelectric coupler is composed of two luminous two extreme tubes and a photoelectric transistor Q03UDCPU PDF.
Light emitting diode two: the input of a photo coupler and the change of electrical signal,
The light signal is generated by the light emitting diode, which is the same as the input signal.
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light Q03UDCPU PDF.
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal.
It is through the input interface circuit to the external switch signal into PLC internal caan accept the digital signal MITSUBISHI Programming Guide Q03UDCPU Manual .
Photoelectric three levels: in the light of the light signal conduction, the degree of light signal and the intensity of the light signal.
The output signal has a linear relationship with the input signal in the linear operating region of the photoelectric coupler MITSUBISHI Programming Guide.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words MITSUBISHI Programming Guide.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4. 4 axes, open collector output type.
2 axis /4 axis /3 axis linear interpolation.
2 axis interpolation.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Maximum pulse output: 200Kpps.
40 pin connector.
Positioning module.
Open collector output.
Differential driver output.
Based on the use oof open collector outputs and differential drive output type 2 types Q03UDCPU Programming Guide.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control Q03UDCPU Manual .
(the command pulse of the open collector positioning module is highest 200kpps.)
Related products
MITSUBISHI
Motion CPU module
Q173DCPU
MITSUBISHI Motion CPU module Q173DCPU
Control axis: maximum 32 axes. Manual pu
MITSUBISHI
Motion CPU module
Q172DCPU
MITSUBISHI Motion CPU module Q172DCPU
Control axis: maximum 8 axes. Peripheral
MITSUBISHI
With Ethernet CPU
Q03UDECPU
MITSUBISHI With Ethernet CPU Q03UDECPU
Input / output points: 4096 points. Num
MITSUBISHI
General purpose CPU
Q03UDCPU
MITSUBISHI General purpose CPU Q03UDCPU
Input / output points: 4096 points. Num