LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI Q00UJCPU-S8 PROGRAMMING Guide Book (Structured Text(ST)) PDF
Product model: Q00UJCPU-S8
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text(ST) PROGRAMMING Guide Book
File language: English
Three-phase 4 wire type.
Measuring circuit number: 3 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc Q00UJCPU-S8 PDF. .
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information Q00UJCPU-S8
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm Q00UJCPU-S8 PDF.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products Q00UJCPU-S8 PDF.
For example, a module can be used to measure other loads from the control panel trunk.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters MITSUBISHI PROGRAMMING Guide Book. Express PCI bus.
Support Japanese, English OS.
Master / local station sharing.
Support Ver.2 CC-Link version.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2 MITSUBISHI PROGRAMMING Guide Book. 5Mbps).
According to the transmission distance, the transmission rate is selected ffrom 2 Q00UJCPU-S8 Manual . 5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module MITSUBISHI PROGRAMMING Guide Book.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information).
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmisssion delay time and the application of the synchronization waiting time Q00UJCPU-S8 PROGRAMMING Guide Book.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Workss2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation Q00UJCPU-S8 Manual .
Related products