"2 axes, SSCNET III type.
2 axis linear interpolation.
2 axis arc interpolation.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis Q00JCPU PDF.
40 pin connector.
Through the SSCNET III cable connection to save wiring, the distance between the station up to 50m.
Absolute position system for determining the origin position is supported by the return data set operation.
In addition, the limit switch of the upper limit, the lower limit switch and the near point block signal input can be directly connected to the servo amplifier,
Thus greatly reducing the wiring requirements Q00JCPU
Easy to achieve high speed, high precision positioning control Q00JCPU PDF.
Support for multiple types of positioning control,
Including 2 ~ 4 axis 2 axis linear interpolation, circular interpolation, speed control and speed / position control, path switching control, constant speed control etc..
In addition, can use the "Configurator-QP GX" and other software,
Easy to set, monitor and debug Q00JCPU PDF. "Express PCI bus.
Support Japanese, English OS.
Multimode fiber optic cable.
Dual loop controller network (control station / common station).
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1 MITSUBISHI Programming Manual. 2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 1556kbps Q00JCPU Manual.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O MITSUBISHI Programming Manual.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information).
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of MITSUBISHI Programming Manual.
Even if the information reaches saturation, it will not affect the link scan time.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the traansmission delay time and the application of the synchronization waiting time Q00JCPU Programming Manual.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Workss2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation Q00JCPU Manual.
Related products
MITSUBISHI
CPU unit
Q2ASCPU
MITSUBISHI CPU unit Q2ASCPU
Input and output points: 512 points. Inp
MITSUBISHI
High performance CPU
Q25HCPU
MITSUBISHI High performance CPU Q25HCPU
Program capacity: 252 K step. Input / ou
MITSUBISHI
Movement CPU
R32MTCPU
MITSUBISHI Movement CPU R32MTCPU
"Axis of control: 32. Program language: