LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI MELDAS 60/60S Series CONNECTION AND MAINTENANCE MANUAL PDF
Product model: MELDAS 60/60S Series
Name: CNC
Brand: MITSUBISHI
Sort: CONNECTION AND MAINTENANCE MANUAL
File language: English
Type: general purpose AC servo amplifier MR-E series.
Rated output: 2.0kw.
Interface type: general purpose pulse interface.
KH003 special mark for Super MR-E MELDAS 60/60S Series PDF.
High performance and easy to operate, reduce work load.
Enhanced system cost performance.
High performance, high precision positioning (servo motor encoder resolution: 131072).
High response.
Suppression of vibration by adaptive vibration suppression control MELDAS 60/60S Series
Using personal computer and servo setup software to optimize tuning.
Has 2 types of interfaces:
Position control and speed control with pulse train interface.
The analog input interface is used for speed control and torque control MELDAS 60/60S Series PDF. The length of the line: 2M.
IP level: IP65.
Direct type.
Bending life: high bending life.
Connector kit for motor electromagnetic brake.
Cable for electromagnetic brake, for HF-KP/HF-MP series (motor shaft with side extraction). MR-J2M multi axis servo amplifier drive unit MELDAS 60/60S Series PDF.
Rated output: 0.4kw.
The accuracy, stability, response characteristtics and operating frequency of the main indicators of the servo control system are four aspects,
Especially in the frequency band width and precision MELDAS 60/60S Series Manual.
Frequency bandwidth of the system, the system frequency response characteristics of the system to reflect the servo system to track the fast MITSUBISHI CONNECTION AND MAINTENANCE MANUAL. Drive: MR-H_ACN series built-in positioning function.
Rated output: 0.6KW.
In servo drive speed closed loop,
Rotor speed measurement accuracy is very important to improve the dynamic and static characteristics of the speed control loop MITSUBISHI CONNECTION AND MAINTENANCE MANUAL.
In order to seek the balance between measurement precision and system cost, incremental photoelectric encoder is generally used as the speed measuring sensor,
The corresponding method is M/T velocity measurement.
Although the M/T measurement method has a certain measurement accuracy and a wide range of measurement,
But this method has its inherent defects,
Mainly includes: the measurement period must be detected at least one complete encoder pulse, limiting the minimum detectable speed MITSUBISHI CONNECTTION AND MAINTENANCE MANUAL MELDAS 60/60S Series CONNECTION AND MAINTENANCE MANUAL.
2 control system for speed control of the timer switch is difficult to maintain synchronization,
Can not guarantee the accuracy of measurement in the situation where the speed change is largger MELDAS 60/60S Series Manual.
Therefore, it is difficult to improve the speed tracking and control performance of servo drive by using the traditional speed loop design method.
Related products