MITSUBISHI L26CPU-PBT  User's Manual (Built-In I/O Function) PDF
Product model: L26CPU-PBT 
Name: CPU Module
Brand: MITSUBISHI
Sort: Built-In I/O Function User's Manual
File language: English
Number of input channels: 4ch.
Input voltage: DC - 10 - 10V.
Input current: DC0 ~ 20mA.
Input voltage: 100 ~ 100mV / minute.
Input thermocouple: K, J, T, E, N, R, S, B, U, L, PL II, W5Re/W26Re L26CPU-PBT  PDF.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50.
Conversion speed: 50ms/ch.
Resolution (voltage / current / micro voltage): 1/20000
Resolution (thermocouple): B, R, S, N, PL II, W5Re/W26Re:0 L26CPU-PBT 3,, K, E, J, T, U, L:0.1.
Temperature measuring resistance: Pt100, JPt100:0.03, /0.1, Pt1000, Pt50:0.1.
Reduce the programming time.
The digital output value can be easily converted (zoom) to any number of functions without the program L26CPU-PBT  PDF.
No need to use ladder diagram conversion program, can reduce the programming time.
Zoom setting example (L60AD4-CM).
The digital output value (20000 ~ 0) of the input range 20mA ~ 4mA is scaled to the value of positive and negative 20000.
Digital filter function
Simply set the parameters, you can eliminate the function of the redundant frequency components L26CPU-PBT  PDF.
Can be selected from low pass filter, high pass filter, medium pass filter.
No need to filter thhe ladder, can reduce programming time L26CPU-PBT  Manual.
In addition, the conversion value of the A/D converted by the filter can be obtained at the same time,
Therefore, the total processing time from the conversion to the filter processing can be shortened MITSUBISHI User's Manual. "Universal output function: source type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet MITSUBISHI User's Manual.
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s MITSUBISHI User's Manual.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programmiing tool L26CPU-PBT  User's Manual.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurrement L26CPU-PBT  Manual.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "