MITSUBISHI L26CPU-P Programming Manual (Common Instruction 1/2) PDF
Product model: L26CPU-P
Name: PLC
Brand: MITSUBISHI
Sort: Common Instruction 1/2 Programming Manual
File language: English
Output points: 8 points (independent of all points).
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point.
Public side mode: no public side (all points of independent contact) L26CPU-P PDF.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called L26CPU-P
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch L26CPU-P PDF.
Communication protocol is a standard Modbus protocol or custom protocol. CC-Link/LT master station.
Transmission speed: 2.5Mbps.
Remote input / output: 1024 points.
16 point mode.
In the cabinet, the device can also respond to high speed L26CPU-P PDF.
CC-Link/LT link scan time to reach the highest 1.2ms (2.5Mbps) at 64 stations,
Excellent response performance is acchieved L26CPU-P Manual.
Can be selected according to the transmission distance 2.5Mbps, 625kbps, 156kbps.
Comfortable environment without network awareness MITSUBISHI Programming Manual.
Parameter settings that do not require any trouble.
Moreover, the transmission speed only through the master module to set, can easily use the remote I/O. Transmission speed: 100Mbps/10Mbps.
MELSOFT connection.
SLMP cross letter (MC protocol).
Communication protocol support function.
E-mail function MITSUBISHI Programming Manual.
Web function.
Collect / change CPU module data from the other side of the device.
SLMP (MC protocol) communication
SLMP is a protocol that uses Ethernet to access SLMP devices from the other device.
If it is possible to follow the SLMP control procedures to send and receive messages to the device,
The communication can be carried out by SLMP MITSUBISHI Programming Manual. MC can also support the previous agreement.
MELSOFT connection
Can be connected with the programming tool Works2 GX and other MELSOFT products.
In addition, through the use of communication tools to support the sale of (MX Component),
Reegardless of the details of the protocol (how to send and receive procedures),
Can create a communication program on the upper side of the system L26CPU-P Programming Manual.
It can easily connect to BACnet and MODBUS /TCP
Communication protocol support functioon
Through the Works2 GX communication protocol support function, can easily set the communication with the other equipment required for the agreement L26CPU-P Manual.
Related products
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L26CPU-P
MITSUBISHI cpu module L26CPU-P
"Universal output function: source type.
MITSUBISHI
cpu module
L06CPU-P
MITSUBISHI cpu module L06CPU-P
"Universal output function: source type.
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type.