LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI L02SCPU-P Programming Manual (Common Instructions) PDF
Product model: L02SCPU-P
Name: PLC
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
Output channel number: 4ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 20 s/ch.
Resolution: 1/20000.
Status of connected devices by means of alarm monitoring L02SCPU-P PDF.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm L02SCPU-P
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement L02SCPU-P PDF.
High speed, smooth continuous analog output.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulated according to the set conversion period L02SCPU-P PDF.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output. CC-Link master / local station.
Transmission speed: 10Mbps.
Remote input / output: 8192 points MITSUBISHI Programming Manual.
Remote register: 2048 words.
Link points in Ver.2.0 CC-Link master station.
Using CC-Link to connect with multiple devices L02SCPU-P Manual .
Rich device using open network CC-Link,
System can be constructed according to the control requirements.
Support Ver.2.0 CC-Link,
So it can be effectively used in the field of large capacity data communication MITSUBISHI Programming Manual.
No need to set the transmission speed of the local station
Automatic tracking function of transmission speed
When used as a local station, the transmission speed of the master station can be automatically tracked,
Do not need to set up in the local station MITSUBISHI Programming Manual.
The transmission speed of the operation can be confirmed by the positive LED of the module. Enter points: 64 points.
Rated input voltage: DC24V.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: 64 points).
External wiring connection: 40 pin connector two.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the parrt can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on L02SCPU-P Manual L02SCPU-P Programming Manual.
Related products
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type.
MITSUBISHI
cpu module
L06CPU-P
MITSUBISHI cpu module L06CPU-P
"Universal output function: source type.
MITSUBISHI
cpu module
L02CPU-P
MITSUBISHI cpu module L02CPU-P
"Universal output function: source type.
MITSUBISHI
cpu module
L02SCPU-CM
MITSUBISHI cpu module L02SCPU-CM
"Universal output function: leakage type