MITSUBISHI FX3U-232-BD INSTALLATION MANUAL PDF
Product model: FX3U-232-BD
Name: function expansion board
Brand: MITSUBISHI
Sort: INSTALLATION MANUAL
File language: English
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Output extension board (transistor output 2 point)
(FX1S and FX1N host general) FX3U-232-BD PDF. Max input / output points: 10 points.
Power supply voltage: 24VDC.
Input points: 6 points.
Output points: 4 points.
Output type: relay.
Power consumption (W): 6.
Weight (kg):0.22.
Size (WxHxD) mm:60x90x49 FX3U-232-BD
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain FX3U-232-BD PDF.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O FX3U-232-BD PDF.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication.
All equipment is digital input and output point.
The total I/O pointss are not more than 30 points, and the input points are less than 16, the output points are less than 14 MITSUBISHI INSTALLATION MANUAL FX3U-232-BD Manual.
Its MT series of PLC can drive 2 way servo or stepper, commonly used in the control system for a simple manipulator. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 45kw.
SLD converter rated current: 93A.
Structure and function: Standard model MITSUBISHI INSTALLATION MANUAL.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup.
No need to adjust the parameters (plus deceleration time or torque, etc MITSUBISHI INSTALLATION MANUAL. ), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drrive motor FX3U-232-BD INSTALLATION MANUAL.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor).
Othher manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving FX3U-232-BD Manual.