MITSUBISHI FX3G-40MT/ESS USER'S MANUAL (Positioning Control Edition) PDF
Product model: FX3G-40MT/ESS
Name: PLC
Brand: MITSUBISHI
Sort: Positioning Control Edition USER'S MANUAL
File language: English
Needle number: 40.
Specification: loose wire connector, 5 sets (0.3mm 2). Power: 7.5kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control FX3G-40MT/ESS PDF.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost FX3G-40MT/ESS
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving. Memory format: flash memory.
Number of steps: up to 64000 steps.
Battery support: do not FX3G-40MT/ESS PDF.
Write, delete method: installed on the PLC through the peripheral devices to write, delete.
Note: with program transfer function. Function: CPU module (internal service power supply).
Input and output points: 80 points.
Power supply capacity (DC5V power): 1100mA.
Power supply capacity (DC24V service power supply): 600mA FX3G-40MT/ESS PDF.
Input / output mode: DC input (drain / source) / transistor (source).
Input points: 40 points.
Output points: 40 points.
The new expansion module is more convenient!
Pioneer products with advanced built-in functions and rich extensibility.
FX5U built-in analog, communication, high speed input and output,
By extending the board and adapter can be easily extended system MITSUBISHI USER'S MANUAL.
In addition, through the high speed system bus,
Can maximize the role of the built-in intelligent functions of the expansion device.
RS-485 communication adapter.
(need FX1N-8AV-BD) MITSUBISHI USER'S MANUAL.
(FX1S and FX1N host general). Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Power: 22kw.
Voltage: 200V.
The surge voltage of the motor can be suppressed when the 400V motor is driven by a frequency converter.
Motor suitable for 5.5 to 37kW MITSUBISHI USER'S MANUAL. Connecting cable for handheld GOT and PLC.
Cable length: 3 meters.
Application: RS-422 connection and RS-232C connection. "MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 1.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is aa power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions FX3G-40MT/ESS Manual.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mmainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX3G-40MT/ESS USER'S MANUAL.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX3G-40MT/ESS Manual. "
Related products
MITSUBISHI
PLC
FX3G-40MT/DS
MITSUBISHI PLC FX3G-40MT/DS
Input and output points: 40 points. Powe
MITSUBISHI
PLC
FX5U-32MT/ESS
MITSUBISHI PLC FX5U-32MT/ESS
Function: CPU module internal service p
MITSUBISHI
PLC
FX3G-40MT/ES-A
MITSUBISHI PLC FX3G-40MT/ES-A
Input points: 24 points. Output points:
MITSUBISHI
PLC
FX3G-40MT/ESS
MITSUBISHI PLC FX3G-40MT/ESS
Input points: 24 points. Output points: