MITSUBISHI FR-F740P-250K-CHT Instruction manual (BASIC) PDF
Product model: FR-F740P-250K-CHT
Name: INVERTER
Brand: MITSUBISHI
Sort: BASIC Instruction manual
File language: English
Max input / output points: 16 points.
Power supply voltage: 24VDC.
Input points: 8 points.
Output points: 8 points.
Output type: relay.
Power consumption: 20W FR-F740P-250K-CHT PDF.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time FR-F740P-250K-CHT
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register FR-F740P-250K-CHT PDF.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications FR-F740P-250K-CHT PDF.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions MITSUBISHI Instruction manual.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable MITSUBISHI Instruction manual. 20 pin connector on both ends of the circular multi-core cable.
Length 3M. Function: RS-485 communication.
CPU module connected to the front of the expansion function of the substrate MITSUBISHI Instruction manual.
The front of the CPU module can be connected to 1 units at most. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 30KW.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is aa power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions FR-F740P-250K-CHT Manual .
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainlyy used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FR-F740P-250K-CHT Instruction manual.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FR-F740P-250K-CHT Manual . "
Related products
MITSUBISHI
3 phase 400V converter
FR-F740P-315K-CHT
MITSUBISHI 3 phase 400V converter FR-F740P-315K-CHT
"MITSUBISHI inverter FR-F740P series. Vo
MITSUBISHI
3 phase 400V converter
FR-F740P-450K-CHT
MITSUBISHI 3 phase 400V converter FR-F740P-450K-CHT
"MITSUBISHI inverter FR-F740P series. Vo
MITSUBISHI
3 phase 400V converter
FR-F740P-45K-CHT
MITSUBISHI 3 phase 400V converter FR-F740P-45K-CHT
"MITSUBISHI inverter FR-F740P series. Vo
MITSUBISHI
3 phase 400V converter
FR-F740P-55K-CHT
MITSUBISHI 3 phase 400V converter FR-F740P-55K-CHT
"MITSUBISHI inverter FR-F740P series. Vo