MITSUBISHI FR-E540-0.4K-CH TECHNICAL MANUAL PDF
Product model: FR-E540-0.4K-CH
Name: TRANSISTORIZED INVERTER
Brand: MITSUBISHI
Sort: TECHNICAL MANUAL
File language: English
Max input / output points: 32 points.
Supply voltage: 100 - 240VAC.
Input points: 16 points.
Output points: 16 points.
Output type: Transistor (source) FR-E540-0.4K-CH PDF.
Power consumption: 40VA.
Weight (kg):0.65.
Size (WxHxD) mm:150x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module FR-E540-0.4K-CH
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register FR-E540-0.4K-CH PDF.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy tto operate FR-E540-0.4K-CH Manual.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program FR-E540-0.4K-CH PDF.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time MITSUBISHI TECHNICAL MANUAL.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 3.7KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible MITSUBISHI TECHNICAL MANUAL.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used MITSUBISHI TECHNICAL MANUAL FR-E540-0.4K-CH TECHNICAL MANUAL. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FR-E540-0.4K-CH Manual.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft.
Related products
MITSUBISHI
3 phase 400V converter
FR-D740-0.4K-CHT
MITSUBISHI 3 phase 400V converter FR-D740-0.4K-CHT
MITSUBISHI inverter FR-D740 series. Volt
MITSUBISHI
Single phase 200V inverter
IS72S-0.4K-CHT
MITSUBISHI Single phase 200V inverter IS72S-0.4K-CHT
Applicale motor capacity: 0.4KW. Rated
MITSUBISHI
3 phase 400V converter
FR-E740-0.4K-CHT
MITSUBISHI 3 phase 400V converter FR-E740-0.4K-CHT
MITSUBISHI inverter FR-E740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-0.4K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-0.4K-CHT
MITSUBISHI inverter FR-A740 series. Volt