LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI FR-CV-7.5K Instruction manual PDF
Product model: FR-CV-7.5K
Name: POWER REGENERATION COMMON CONVERTER
Brand: MITSUBISHI
Sort: Instruction manual
File language: English
Max input / output points: 128 points.
Supply voltage: 100 - 240VAC.
Input points: 64 points.
Output points: 64 points.
Output type: transistor.
Power consumption: 100VA FR-CV-7.5K PDF.
Weight (kg):1.8.
Size (WxHxD) mm:350x90x87.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time FR-CV-7.5K
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register FR-CV-7.5K PDF.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications FR-CV-7.5K PDF.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions MITSUBISHI Instruction manual.
On the right side of the FX2N series can be connected to the input and output expansion modules annd special function modules FR-CV-7.5K Manual .
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable MITSUBISHI Instruction manual. Max input / output points: 10 points.
Power supply voltage: DC24V.
Input points: 6 points.
Output points: 4 points.
Output type: relay.
Power consumption (W): 19.
Weight (kg):0.3.
Size (WxHxD) mm:60x90x75 MITSUBISHI Instruction manual.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no bbattery, easy to maintain FR-CV-7.5K Instruction manual.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BBD board to extend a small amount of I/O FR-CV-7.5K Manual .
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication.
Related products
MITSUBISHI
Common DC bus converter
FR-CV-H15K
MITSUBISHI Common DC bus converter FR-CV-H15K
Power: 15kw. Voltage: 400V. There are 10
MITSUBISHI
3 phase 400V converter
FR-L740-7.5K-CHT
MITSUBISHI 3 phase 400V converter FR-L740-7.5K-CHT
MITSUBISHI inverter FR-L740 series. Volt
MITSUBISHI
Brake unit
FR-BU2-7.5K
MITSUBISHI Brake unit FR-BU2-7.5K
Power: 7.5kw. Voltage: 200V. Purpose: hi
MITSUBISHI
Common DC bus converter
FR-CV-7.5K
MITSUBISHI Common DC bus converter FR-CV-7.5K
Power: 7.5kw. Voltage: 200V. There are 1