Parameter setting can be carried out without the power supply of the inverter.Input and output points: 24 points.
Power supply: DC24V.
Input points: 14 points FR-A740-500K-CHT PDF.
Output points: 10 points.
Output form: transistor output (source).
Power consumption: 21W.
Weight: 0.55KG.
Outline dimension: 90x90x86mm.
FX3GE on the performance of the FX3GA increased analog input / output and Ethernet communication and other built-in features FR-A740-500K-CHT
Applicable to a wide variety of applications.
Basic unit: 24/40 point.
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost PLC.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points FR-A740-500K-CHT PDF.
A versatile PLC.
Built in CPU, power supply, input and output, analog input and output, Ethernet port, can be used immediately after the purchase.
High speed operation.
Basic instructions: 0.21 s/ instruction FR-A740-500K-CHT PDF.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function. The operation, monitoring, parameter modification and other operations can be carried out by computer or PLC.Adapter RS-232 communication (FX3U- - racy -BD) MITSUBISHI INSTRUCTION MANUAL. "MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 30KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes MITSUBISHI INSTRUCTION MANUAL.
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection).
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way MITSUBISHI INSTRUCTION MANUAL.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is aa power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions FR-A740-500K-CHT Manual.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainnly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FR-A740-500K-CHT INSTRUCTION MANUAL.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FR-A740-500K-CHT Manual. "
Related products
MITSUBISHI
3 phase 400V converter
FR-A740-0.4K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-0.4K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-75K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-75K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-18.5K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-18.5K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-F740P-500K-CHT
MITSUBISHI 3 phase 400V converter FR-F740P-500K-CHT
"MITSUBISHI inverter FR-F740P series. Vo