LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI FR-A740-450K-CHT INSTRUCTION MANUAL (BASIC) PDF
Product model: FR-A740-450K-CHT
Name: INVERTER
Brand: MITSUBISHI
Sort: BASIC INSTRUCTION MANUAL
File language: English
Power: 37kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control FR-A740-450K-CHT PDF.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving FR-A740-450K-CHT Max input / output points: 32 points.
Supply voltage: 100 - 240VAC.
Input points: 16 points.
Output points: 16 points.
Output type: relay.
Power consumption: 35W FR-A740-450K-CHT PDF.
Weight (kg):0.65.
Size (WxHxD) mm:150x90x86.
Faster and more efficient. Support high speed control and network communication, and have the function of data recording.
High speed, large capacity, multi-function high-end machine.
FX3U supports high speed processing, CC-Link communication, network communication, analog control and advanced positioning system FR-A740-450K-CHT PDF.
Connected to the CC-Link, including the remote I/O, the maximum input and output control points up to 384 points,
Can correspond to a variety of field needs, the use of its scalability and flexibility to expand the scope of application of the control system MITSUBISHI INSTRUCTION MANUAL.
Third generation high function micro programmable controller.
High speed, high efficiency, high performance, large capacity, and new features.
Built in high speed processing and positioning.
Control points: maximum 256 points.
Use CC-Link remote I/O for 384 points MITSUBISHI INSTRUCTION MANUAL. "MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 5.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) MITSUBISHI INSTRUCTION MANUAL.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is aa power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions FR-A740-450K-CHT Manual.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainnly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FR-A740-450K-CHT INSTRUCTION MANUAL.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FR-A740-450K-CHT Manual. "
Related products
MITSUBISHI
3 phase 400V converter
FR-A740-280K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-280K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-7.5K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-7.5K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-3.7K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-3.7K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-160K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-160K-CHT
MITSUBISHI inverter FR-A740 series. Volt