MITSUBISHI FR-A740-11K-CHT PLC FUNCTION PROGRAMMING MANUAL PDF
Product model: FR-A740-11K-CHT
Name: INVERTER
Brand: MITSUBISHI
Sort: PLC FUNCTION PROGRAMMING MANUAL
File language: English
Through a series of holes available to install FR-A800 using the original FR-A200 series.MITSUBISHI inverter FR-A720 series.
Voltage level: 3 phase 200V FR-A740-11K-CHT PDF.
Frequency converter capacity: 5.5KW.
Inverter output for the PWM wave, containing more harmonic.
Frequency conversion power sensor through the input voltage and current signals to exchange sampling,
Sampling value through cable, optical fiber and other transmission systems and digital input frequency conversion power analyzer,
The sampling value of the voltage and current is calculated by the digital input frequency conversion power analyzer,
It can obtain the parameters such as voltage effective value, current effective value, fundamental wave voltage, fundamental current, harmonic voltage, harmonic current, active power, fundamental wave power and harmonic power FR-A740-11K-CHT PDF FR-A740-11K-CHT Power: 220kw.
Voltage: 400V.
The power factor of the input power factor is up to 0 FR-A740-11K-CHT PDF. 99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function. MMITSUBISHI inverter FR-A740 series FR-A740-11K-CHT Manual.
Voltage level: 3 phase 400V.
Frequency converter capacity: 75KW.
Frequency converter is the application of frequency conversion technology and micro electronics technology, by changing the motor operating power frequency mode to control the AC motor power control equipment MITSUBISHI PLC FUNCTION PROGRAMMING MANUAL.
The converter is composed of rectifier (AC), filter, inverter (DC), braking unit, driving unit, micro processing unit of the detection unit MITSUBISHI PLC FUNCTION PROGRAMMING MANUAL.
Inverter by the internal IGBT to adjust the output power supply voltage and frequency,
According to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition to the,
Inverter has a lot of protection functions, such as over current, over voltage, overload protection and so on MITSUBISHI PLC FUNCTION PROGRAMMING MANUAL. Total input and output points: 8 points.
Input points: 8 points.
Output type: AC100V.
FX2N extension module.
The expansion module is an input and output expansion device of the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect FR-A740-11K-CHT PLC FUNCTION PROGRAMMING MANUAL.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V FR-A740-11K-CHT Manual.
The number of connection points depends on the basic unit and the expansion unit.
Last one: MITSUBIS...
next one: MITSUBIS...
Related products
MITSUBISHI
3 phase 400V converter
FR-A740-315K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-315K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-355K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-355K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-160K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-160K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-22K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-22K-CHT
MITSUBISHI inverter FR-A740 series. Volt