MITSUBISHI FR-A740-11K-C9 INSTRUCTION MANUAL (Applied) PDF
Product model: FR-A740-11K-C9
Name: INVERTER
Brand: MITSUBISHI
Sort: Applied INSTRUCTION MANUAL
File language: English
Extending the device for FX1, PLC FX2, on PLC FX2N.
Need to use the conversion cable. Can be used as a screw relay terminal. Negative common end useMITSUBISHI inverter series: FR-F840 FR-A740-11K-C9 PDF.
Voltage level: three phase 400V.
Power: 1.5kw.
SLD converter rated current: 3.8A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed FR-A740-11K-C9
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption FR-A740-11K-C9 PDF.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control FR-A740-11K-C9 PDF. Function extension board for RS-422 communication.
No DC24V consumption, no occupancy of the input output (FX1S and FX1N of the host computer). Power: 30kw.
Voltage: 400V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control MITSUBISHI INSTRUCTION MANUAL.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost.
Renewable energy can be used for other frequency converter, exceess energy back to the grid, to achieve energy saving MITSUBISHI INSTRUCTION MANUAL FR-A740-11K-C9 Manual. Power: 400kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function MITSUBISHI INSTRUCTION MANUAL. Input / output type: DC input (drain / source).
Input points: 16 points.
Input and output points: 16 points.
Because all models of FX series are built in high speed counter,
So the high speed control can be realized by the simple procedure.
The input of the basic unit is built in the anti jitter filter,
One part as digital filter,
Sensitivity adjustment unit can reach 1ms.
Using high speed counter automatically adjusted to the minimum value.
Through the high cost of the built-in positioning function and the expansion function to increase the number of control axis.
Extended function expansion board and special adapter,
Data links and communication with external serial devices.
FX2N extension module.
The expansion module is an input and output expansion device off the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect FR-A740-11K-C9 INSTRUCTION MANUAL.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V FR-A740-11K-C9 Manual.
The number of connection points depends on the basic unit and the expansion unit.
Related products
MITSUBISHI
3 phase 400V converter
FR-A740-315K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-315K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-110K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-110K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-45K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-45K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-37K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-37K-CHT
MITSUBISHI inverter FR-A740 series. Volt