MITSUBISHI AY80 User's Manual PDF
Product model: AY80
Name: I/O Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Storage capacity: 16MB.
Applicable models: A985 (-V) /A975/A970/A960GOT (-B). Input points: 32 points.
Voltage: DC12/24V.
Current: 2.5/5mA.
Response time: 0 AY80 PDF. 2ms.
8 points / a common end.
Positive / negative sharing.
38 point terminal station.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read AY80
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh AY80 PDF.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling AY80 PDF.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive MITSUBISHI User's Manual.
Different series of diffferent models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference AY80 Manual. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC MITSUBISHI User's Manual.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear MITSUBISHI User's Manual. Enter 32 points.
2/5mA DC12/24V.
Response time: 10ms.
32 point 1 public.
Output 32 points.
DC12/24V.
Leakage current: 0.1mA OFF.
Response time: 1ms.
32 point 1 public.
Protection function.
Surge.
40 pin connector.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input commbination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order AY80 User's Manual.
So, sometimes also known as the order control.
And seqquential control is divided into manual, semi-automatic or automatic AY80 Manual.
And the control principle is decentralized, centralized and hybrid control three.
Related products
MITSUBISHI
Transistor output module
AY51-S1
MITSUBISHI Transistor output module AY51-S1
Output points: 32 points. Voltage: DC12/
MITSUBISHI
Relay output module
AY11
MITSUBISHI Relay output module AY11
Output points: 16 points. Voltage: DC24V
MITSUBISHI
Transistor output module
AY81EP
MITSUBISHI Transistor output module AY81EP
Output points: 32 points. Voltage: DC12/
MITSUBISHI
Bidirectional thyristor output module
AY81C
MITSUBISHI Bidirectional thyristor output module AY81C
Output points: 32 points. Voltage: DC24V