LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI AJ71LR21 Reference Manual PDF
Product model: AJ71LR21
Name: Data Link System
Brand: MITSUBISHI
Sort: Reference Manual
File language: English
Screw, 2 piece type terminal
Thermocouple Input module.
Number of channels: 4 channels.
Number of stations: 1 stops.
Station type: remote equipment station AJ71LR21 PDF.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on step by step AJ71LR21
If you do not meet the requirements, the hardware and procedures for adjustment AJ71LR21 PDF.
Usually only need to modify the part of the program can be.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram AJ71LR21 PDF.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced MITSUBISHI Reference Manual . Input and output points: 1024 points.
Input / output data points: 1024 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure MITSUBISHI Reference Manual AJ71LR21 Manual .
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance MITSUBISHI Reference Manual .
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a mmeasure of how much the user application can store the number of indicators AJ71LR21 Reference Manual .
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words AJ71LR21 Manual . Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
Coaxial cable module
AJ71LR21
MITSUBISHI Coaxial cable module AJ71LR21
3C-2V/5C-2V coaxial cale. Doule loop.
MITSUBISHI
Ethernet module
AJ71QE71-B5
MITSUBISHI Ethernet module AJ71QE71-B5
Ethernet network module 10BASE5 Control
MITSUBISHI
Serial communication module
AJ71QC24-R2
MITSUBISHI Serial communication module AJ71QC24-R2
RS-232 2 channel. Transfer speed: 0.3-19
MITSUBISHI
Network module
A1SJ71QLR21
MITSUBISHI Network module A1SJ71QLR21
3C-2V/5C-2V coaxial cale etween doule