Product model: AD75P2-S3
Name: Positioning Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Output type: relay.
Output points: 12 points.
Load voltage: AC240/DC24.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 4.
Sequential function flow chart language is designed to satisfy the sequential logic control AD75P2-S3 PDF.
The process of sequential process action is divided into steps and transformation conditions,
According to the transfer condition, the control system is distributed in the function flow sequence,
Step by step according to the sequence of actions AD75P2-S3
Each step represents a control function, represented by the box.
In the box, the ladder logic is used to complete the task of the corresponding control function AD75P2-S3 PDF.
This programming language makes the program structure clear and easy to read aand maintain,
Greatly reduce the programming workload, shorten the programming and debugging time AD75P2-S3 Manual.
Used in the system of the size of the school, procedures for more complex occasions AD75P2-S3 PDF.
Sequence function flow chart programming language features: to function as the main line, in accordance with the functional flow of the order of distribution, clear, easy to understand the user program,
Avoid the defect of ladder diagram or other languages,
At the same time, the use of ladder language to avoid the use of ladder programming,
Due to the complicated mechanical interlock, the structure of the user program is complex and difficult to understand,
User program scan time is also greatly reduced MITSUBISHI User's Manual. Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 1 MITSUBISHI User's Manual. 5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.5A.
External connection: 1 line /1 line type MITSUBISHI User's Manual AD75P2-S3 User's Manual.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AD75P2-S3 Manual.