MITSUBISHI A951GOT-QTBD Operating Manual (SW4D5C-GOTR-PACKE compatible Extended/Option Functions Manual) PDF
Product model: A951GOT-QTBD
Name: touch screen
Brand: MITSUBISHI
Sort: SW4D5C-GOTR-PACKE compatible Extended/Option Functions Manual Operating Manual
File language: English
A set of 5 (LOGO removable, man-machine interface provides one).
Applicable model: A975/970GOT (-B). 8 slots.
Power supply unit.
QnA series unit installation A951GOT-QTBD PDF.
High speed access.
CE logo fit.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest A951GOT-QTBD
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point A951GOT-QTBD PDF.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program innto PLC internally recognized by the user to compile the program A951GOT-QTBD PDF A951GOT-QTBD Manual.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage MITSUBISHI Operating Manual.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load MITSUBISHI Operating Manual.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action. Input type: DC input, positive common end.
Input points: 4 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type MITSUBISHI Operating Manual.
Output points: 4 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.5A.
Externall connection: 3 line /2 line type A951GOT-QTBD Operating Manual.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A951GOT-QTBD Manual.
Related products
MITSUBISHI
6 inch man machine interface
A951GOT-QSBD
MITSUBISHI 6 inch man machine interface A951GOT-QSBD
Series Name: A951GOT. Size: 6 inches. Re
MITSUBISHI
6 inch man machine interface
A951GOT-LBD
MITSUBISHI 6 inch man machine interface A951GOT-LBD
Series Name: A951GOT. Size: 6 inches. Re
MITSUBISHI
6 inch man machine interface
A951GOT-QTBD
MITSUBISHI 6 inch man machine interface A951GOT-QTBD
Series Name: A951GOT. Size: 6 inches. Re
MITSUBISHI
6 inch man machine interface
A951GOT-QLBD
MITSUBISHI 6 inch man machine interface A951GOT-QLBD
Series Name: A951GOT. Size: 6 inches. Re