LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI A68B-UL User's Manual PDF
Product model: A68B-UL
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Input type: DC input, negative public end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA A68B-UL PDF.
External connection: 2~4 line type.
Waterproof connector type.
Strong waterproof type of IP67 protection grade.
No need to stop the system can be replaced module.
Without the use of tools can be a simple connection, save time.
Terminal resistor built-in A68B-UL
Can be installed along the 6 direction.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong A68B-UL PDF.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness A68B-UL PDF.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. Cable length: 30 meters.

For QCPU and GOT (need A9GT-QCNB) connection A68B-UL Manual.
For the connection between GOT and GOT. 3C-2V/5C-2V coaxial cable between double loop PC (control station / common station) / remote I/O network (remote master station) MITSUBISHI User's Manual.
Q mode.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program MITSUBISHI User's Manual.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive MITSUBISHI User's Manual.
Semiconductor circuit with memory function.
System program memory and user memory.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user proogram to do the compiler to compile the process of interpretation A68B-UL User's Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
User memory: user program storage area and work data storage area.
Composed of random access memory (RAM) A68B-UL Manual. User use.
Power cut off. Commonly used efficient lithium battery as a backup power supply, life is generally 3~5 years.
Related products
MITSUBISHI
Extended bottom plate
A68B
MITSUBISHI Extended bottom plate A68B
8 slots. To install the power supply. Fo
MITSUBISHI
Analog output module
A68DAI-S1
MITSUBISHI Analog output module A68DAI-S1
8 channels. Input: DC0 20mA. Output r
MITSUBISHI
Analog output module
A68DAV
MITSUBISHI Analog output module A68DAV
8 channels. Input: DC-10 10V. Output
MITSUBISHI
Analog input module
A68ADC
MITSUBISHI Analog input module A68ADC
8 channels. Input: DC-10 10V/DC4 20m