LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI A3UCPU User's Manual (Hardware) PDF
Product model: A3UCPU
Name: PLC
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
RS-232 2 channel.
Transmission speed: 2 channel total is 115.2kbps.
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system A3UCPU PDF.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system A3UCPU
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state of the machine movement,
Make maintenance work efficiency also greatly improved A3UCPU PDF.
Q series PLC in the use of CC-Link function better,
And easier to use. Coaxial data link anomaly station A3UCPU PDF.
Extension sub station.
Redundant operation switch of master station. Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: NNo A3UCPU Manual .
Rated load voltage / current: DC12V/DC24V/0.5mA.
External connection: 1 wire MITSUBISHI User's Manual.
Type of input and output terminal.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. Optional features of memory card (A/FX compatible).
Non extended memory.
Applicable models: A985 (-V) /975/970/A960GOT (-B) /A956WGOT MITSUBISHI User's Manual. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
External connection: 2~4 line type.
Waterproof connector type.
Strong waterproof type of IP67 protection grade.
No need to stop the system can be replaced module MITSUBISHI User's Manual.
Without the use of tools can be a simple connection, save time.
Terminal resistor built-in.
Can be installed along the 6 direction.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong A3UCPU User's Manual.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too guarantee the timeliness A3UCPU Manual .
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
Related products
MITSUBISHI
General high speed CPU
Q26UDVCPU
MITSUBISHI General high speed CPU Q26UDVCPU
Input / output points: 4096 points. Inpu
MITSUBISHI
General purpose CPU
Q04UDHCPU
MITSUBISHI General purpose CPU Q04UDHCPU
Input / output points: 4096 points. Num
MITSUBISHI
General purpose CPU
Q06UDHCPU
MITSUBISHI General purpose CPU Q06UDHCPU
Input / output points: 4096 points. Num
MITSUBISHI
Programmable logic controller CPU
R16CPU
MITSUBISHI Programmable logic controller CPU R16CPU
Operation control mode: stored procedure