LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI A2CCPUP21 User's Manual PDF
Product model: A2CCPUP21
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Enter points: 64 points.
Voltage: DC12/24V.
Current: 3/7mA.
Response time: 10ms.
32 points / a common end.
Cathode common.
40 pin connector.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation A2CCPUP21 PDF.
Read only memory. Manufacturers use, content can not be changed, power does not disappear A2CCPUP21
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive A2CCPUP21 PDF.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC A2CCPUP21 PDF.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read MITSUBISHI User's Manual.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions MITSUBISHII User's Manual A2CCPUP21 Manual .
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay. CPU-A8UPU/A8PUJ connection.For A6TBXY36/A6TBXY54/A6TBX70E (common cathode; drain type) long 0 MITSUBISHI User's Manual. 5m.MELSECNET/10.
Inter-PC fiber loop. Type of input: DC leakage.
Input points: 16 points.
Input voltage: DC24.
Input current: 7mA.
Connection mode: terminal row.
Common common point: 16.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations.
In the case of the computer for the PLC handheld programmer compile user program.
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC.
The characteristics of instruction table programming langguage is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-tto-one correspondence between the ladder diagram and the ladder diagram A2CCPUP21 Manual A2CCPUP21 User's Manual. Its characteristics are basically consistent with the ladder diagram language.
Related products
MITSUBISHI
CPU unit
A2CCPUR21
MITSUBISHI CPU unit A2CCPUR21
Input and output points: 512 points. Inp
MITSUBISHI
CPU unit
A2ACPUP21
MITSUBISHI CPU unit A2ACPUP21
Input and output points: 512 points. Inp
MITSUBISHI
CPU unit
A3ACPUP21
MITSUBISHI CPU unit A3ACPUP21
Input and output points: 2048 points. In
MITSUBISHI
CPU unit
A2NCPUP21
MITSUBISHI CPU unit A2NCPUP21
Input and output points: 512 points. Inp