LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI A2CCPU-D24V Programming Manual (Fundamentals) PDF
Product model: A2CCPU-D24V
Name: PLC
Brand: MITSUBISHI
Sort: Fundamentals Programming Manual
File language: English
AC input points: 32 points.
Input voltage and current: AC100 ~ 10mA, 120V.
Response time: 35ms.
16 point /1 a public side.
Bidirectional thyristor output points: 24 points A2CCPU-D24V PDF.
Output voltage and current: AC100 ~ 240V, 0.6A/1 point, 2.4A/1 public end.
Response time: 0.5Hz1ms.
8 point /1 a public end, 4 point /1 a public end.
36 point terminal table * 2.
Number of stations: 8 stops.
Compact remote I/O unit A2CCPU-D24V
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system A2CCPU-D24V PDF.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the maanagement of the terminal production information can be realized,
On the centralized management of the state of the machine movement,
Make maintenance work efficiency also greatly improved A2CCPU-D24V PDF A2CCPU-D24V Manual .
Q series PLC in the use of CC-Link function better,
And easier to use MITSUBISHI Programming Manual.
Mitsubishi Co PLC network inherited the traditional use of the MELSEC network,
And make it better in terms of performance, function, easy to use etc..
Provides a layer of three layers of clear network, to provide the most suitable network products for a variety of uses MITSUBISHI Programming Manual.
The information layer /Ethernet (Ethernet) information layer is the highest level of the network system,
Mainly in the PLC, the device controller and production management with PC transmission between production management information, quality management information and the operation of equipment, etc MITSUBISHI Programming Manual. ,
Information layer using the most common Ethernet.
It is not only able to connect the PC system UNIX, windows system, etc.,
And can connect a variety of FA devices.
The Ethernett module has the function of Internet e-mail receiving and sending,
The user can send and receive the production information conveniently in any place of the world,
Build a remote monitoring management system A2CCPU-D24V Programming Manual.
At the same time, tthe use of the Internet FTP server functions and MELSEC protocol can be very easy to achieve the program upload / download and transfer of information A2CCPU-D24V Manual .