LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI A2ACPUR21-S1 Programming Manual (Fundamentals) PDF
Product model: A2ACPUR21-S1
Name: PLC
Brand: MITSUBISHI
Sort: Fundamentals Programming Manual
File language: English
Input type: DC input, positive public end / negative public end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA A2ACPUR21-S1 PDF.
External connection: 3 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A2ACPUR21-S1 Output points: 16 points.
Voltage: AC100 ~ 240V A2ACPUR21-S1 PDF.
OFF leakage current: 3mA.
Output type: bidirectional controlled silicon.
8 points / a common end.
20 point terminal station.
With short circuit protection.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process A2ACPUR21-S1 PDF. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read A2ACPUR21-S1 Manual .
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program MITSUBISHI Programming Manual.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode MITSUBISHI Programming Manual.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference MITSUBISHI Programming Manual. Therefore PLC selection,
Under the premise of meeting the control reqquirements,
Should consider the best performance to price ratio, a reasonable choice of PLC A2ACPUR21-S1 Programming Manual.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation A2ACPUR21-S1 Manual .
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products
MITSUBISHI
CPU unit
A2ACPUP21-S4
MITSUBISHI CPU unit A2ACPUP21-S4
Input and output points: 1024 points. In
MITSUBISHI
CPU unit
A2ACPUP21-S3
MITSUBISHI CPU unit A2ACPUP21-S3
Input and output points: 512 points. Inp
MITSUBISHI
CPU unit
A2ACPUP21
MITSUBISHI CPU unit A2ACPUP21
Input and output points: 512 points. Inp
MITSUBISHI
CPU unit
A2ACPUR21-S1
MITSUBISHI CPU unit A2ACPUR21-S1
Input and output points: 1024 points. In