LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI A2ACPUP21-S3 User's Manual PDF
Product model: A2ACPUP21-S3
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
26 point with the connection transformation adapter 16 type 1 point input CC-Link unit to install the special connection transformation adapterInput type: DC input, positive public end / negative public end A2ACPUP21-S3 PDF.
Input points: 32 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup A2ACPUP21-S3
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A2ACPUP21-S3 PDF. Program 2 channel connection, AnCPU/QnACPU use.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add A2ACPUP21-S3 PDF.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations. DC input points: 16 points.
Input voltage and current: 3/7mA, DC12/24V MITSUBISHI User's Manual.
Response time: 110ms A2ACPUP21-S3 Manual .
Positive pole sharing.
16 point /1 a public side.
Output points: 12 points.
Output voltage and current: DC12/24V, 0.5A/1 point, 3.2A/1 common end.
Response time: 2ms.
8 point /1 a public end, 4 point /1 a public end.
Output form: transistor output, leakage type MITSUBISHI User's Manual.
36 point terminal station.
Number of stations: 4 stops.
Compact remote I/O unit.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system MITSUBISHI User's Manual.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and thhe timeliness is strong A2ACPUP21-S3 User's Manual.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too guarantee the timeliness A2ACPUP21-S3 Manual .
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
Related products
MITSUBISHI
CPU unit
A2ACPUP21-S4
MITSUBISHI CPU unit A2ACPUP21-S4
Input and output points: 1024 points. In
MITSUBISHI
CPU unit
A3NCPUP21-S3
MITSUBISHI CPU unit A3NCPUP21-S3
Input and output points: 2048 points. In
MITSUBISHI
Moving CPU unit
A73CPUP21-S3
MITSUBISHI Moving CPU unit A73CPUP21-S3
Special multi axis positioning controlle
MITSUBISHI
CPU unit
A2ACPUR21
MITSUBISHI CPU unit A2ACPUR21
Input and output points: 512 points. Inp