MITSUBISHI A2ACPUP21-S3 Programming Manual (Common Instructions) PDF
Product model: A2ACPUP21-S3
Name: Programmable Logic Controller
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
DC input points: 2 points.
Input voltage and current: 7mA, DC24V.
Input response time: 10ms.
2 point /1 a public side.
Positive / negative sharing.
Output points: 2 points A2ACPUP21-S3 PDF.
Output voltage and current: DC24V/AC240V, 2A/1 point, 4A/1 common end.
Output response time: 2ms.
2 point /1 a public side.
Output form: relay.
16 point terminal station.
MITSUBISHI PLC protection and chain procedures A2ACPUP21-S3
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system A2ACPUP21-S3 PDF.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc A2ACPUP21-S3 PDF. .
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program MITSUBISHI Programming Manual .
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. AC input points: 32 points.
Input voltage and current: AC100 ~ 10mA, 120V.
Response time: 25ms.
16 point /1 a public side MITSUBISHI Programming Manual .
Relay output points: 24 points.
Output voltage and current: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Response time: 12ms.
8 point /1 a public side.
36 point terminal table * 2.
Number of stations: 8 stops.
Compact remote I/O unit.
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system MITSUBISHI Programming Manual .
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-mmachine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state of the machine movement,
Make maintenance work efficiency also greatly improved A2ACPUP21-S3 Manual.
Q series PLC in the use of CC-Link function better,
And easier to use.
Mitsubishi Co PLC network inherited the traditional use of the MELSEC network,
And make it better in terms of performance, function, easy to use etc..
Provides a layer of three layers of clear network, to provide the most suitable network products for a variety of uses.
The information layer /Ethernet (Ethernet) information layer is the highest level of the network system,
Mainly in the PLC, the device controller and production management with PC transmission between production management information, quality management information and the operation of equipment, etc.,
Information layer using the most common Ethernet.
It is not only able to connect the PC system UNIX, windows system, etc.,
And can connect a variety of FA devices.
The Ethernett module has the function of Internet e-mail receiving and sending,
The user can send and receive the production information conveniently in any place of the world,
Build a remote monitoring management system A2ACPUP21-S3 Programming Manual .
At the same time, tthe use of the Internet FTP server functions and MELSEC protocol can be very easy to achieve the program upload / download and transfer of information A2ACPUP21-S3 Manual.
Related products
MITSUBISHI
CPU unit
A2ACPUP21-S4
MITSUBISHI CPU unit A2ACPUP21-S4
Input and output points: 1024 points. In
MITSUBISHI
CPU unit
A3NCPUP21-S3
MITSUBISHI CPU unit A3NCPUP21-S3
Input and output points: 2048 points. In
MITSUBISHI
CPU unit
A3ACPUP21-S3
MITSUBISHI CPU unit A3ACPUP21-S3
Input and output points: 2048 points. In
MITSUBISHI
CPU unit
A2NCPUP21-S3
MITSUBISHI CPU unit A2NCPUP21-S3
Input and output points: 512 points. Inp