MITSUBISHI A1SY40 User's Manual PDF
Product model: A1SY40
Name: I/O Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
I/O slots: 8 slots.
Outline dimension: 430*130.
CPU basic board can be plugged into 1 power modules,
1 CPU components and a maximum of 2, 3, 5, or 8 single slot size special function components and I/O components are respectively inserted and arranged A1SY40 PDF.
Expansion ports are arranged on both sides of the base plate,
For connecting the expansion board for.
Up to 3 extension substrates. Reader writer 1 channel connection, AnSCPU/QnASCPU A1SY40
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work A1SY40 PDF A1SY40 PDF.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the useer according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work MITSUBISHI User's Manual MITSUBISHI User's Manual A1SY40 Manual. JEMANET (OPCN-1) interface unit from the station MITSUBISHI User's Manual.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomeenon is called the I/O delay time effect A1SY40 User's Manual.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CCPU A1SY40 Manual.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.
Related products
MITSUBISHI
Serial communication module
A1SJ71QC24
MITSUBISHI Serial communication module A1SJ71QC24
RS-232 1 channel. RS-422/485 1 channel.
MITSUBISHI
output module
A1SY68A
MITSUBISHI output module A1SY68A
Output type: transistor source / drain t
MITSUBISHI
Relay output module
A1SY18A
MITSUBISHI Relay output module A1SY18A
Output type: relay. Output points: 8 poi