MITSUBISHI A1SD75M2 User's Manual PDF
Product model: A1SD75M2
Name: POsitioning Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
TFT color LCD touch screen to replace the backlight.
Applicable model: A985GOT-V. Input and output points: 1024 points.
Input / output data points: 1024 points A1SD75M2 PDF.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Optical data communication line.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process A1SD75M2 When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh A1SD75M2 PDF.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count A1SD75M2 PDF.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units MITSUBISHI User's Manual. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4. NSD servo system MITSUBISHI User's Manual.
A73CPU (P21/R21) -S3 dedicated.
Relay output interface circuit of PLC
Working pprocess: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage MITSUBISHI User's Manual A1SD75M2 Manual.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined acccording to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point A1SD75M2 User's Manual.
Taking into account the future adjustment and expansion,
In general should be estimaated on the total number of points plus the amount of spare 20%~30% A1SD75M2 Manual.
The following describes the centralized control system I/O points of the estimate.
Related products
MITSUBISHI
The PC card interface unit
A1SD59J-MIF
MITSUBISHI The PC card interface unit A1SD59J-MIF
SRAM PC card. Applicale models: A95_GOT
MITSUBISHI
Reader module
A1SD32ID2
MITSUBISHI Reader module A1SD32ID2
AnS, QnAS us connection, the reader to
MITSUBISHI
High speed counting module
A1SD62D
MITSUBISHI High speed counting module A1SD62D
Numer of channels: 2 channels. Input si